Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 28
Filter
1.
Rev. odontol. UNESP (Online) ; 52: e20230006, 2023. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1442091

ABSTRACT

Introduction: with the technological advance in dentistry, light-polymerized three-dimensional (3D) printing resins had become an alternative for the manufacture of occlusal splint splints. Objective: the present study aimed to analyze the flexural strength of a resin for 3D printing compared to conventional acrylic resins (chemically activated and thermally activated), under the influence of thermocycling. Material and method: 60 specimens were made, which were distributed in six experimental groups (n = 10), according to the resin employed (chemically activated acrylic resin, thermally activated acrylic resin and 3D printing resin) and the treatment received (control and thermocycling). The specimens were submitted to flexural strength by the three-point flexural test. Result: data analysis showed that the material factor (<0.0001) and the thermocycling factor (p = 0.0096) influenced flexural strength, however, the interaction between the two factors did not (p = 0.9728). Conclusion: it was concluded that 3D printing resins presented the lowest flexural resistance to acrylic resins, especially when submitted to thermocycling.


Introdução: com o avanço tecnológico dentro da odontologia, as resinas fotopolimerizáveis para impressão tridimensional (3D) se tornaram uma alternativa para a fabricação de dispositivos interoclusais. Objetivo: o presente trabalho teve como objetivo analisar a resistência flexural de uma resina para impressão tridimensional comparada com resinas acrílicas convencionais (quimicamente ativada e termicamente ativada), sob a influência da termociclagem. Material e método: foram confeccionados 60 corpos de prova, que foram distribuídos aleatoriamente em seis grupos experimentais (n=10), de acordo com a resina utilizada (resina acrílica ativada quimicamente, resina acrílica ativada termicamente e resina para impressão 3D) e com o tratamento recebido (controle e termociclagem). Os corpos de prova foram submetidos ao ensaio de flexão de três pontos para determinação da resistência flexural. Resultado: a análise dos dados demonstrou que o fator material (<0.0001) e o fator termociclagem (p=0.0096) influenciaram a resistência flexural, entretanto, a interação entre os dois fatores não (p=0.9728). Conclusão: deste modo podemos concluir que a resina para impressão 3D apresentou desempenho inferior às resinas acrílicas, especialmente quando submetida a termociclagem.


Subject(s)
Acrylic Resins , Occlusal Splints , Resins , Printing, Three-Dimensional , Flexural Strength
2.
Rev. Odontol. Araçatuba (Impr.) ; 41(1): 47-52, jan.-abr. 2020. ilus
Article in Portuguese | LILACS, BBO | ID: biblio-1102380

ABSTRACT

O tratamento endodôntico frequentemente leva à perda de parte coronária de um elemento dentário, seja pelo enfraquecimento de sua estrutura, por lesões traumáticas ou por cárie. Desde que em condições favoráveis, esses dentes podem ser restaurados por meio de retenção adequada provida por meio de retentores intrarradiculares. Os pinos de quartzo utilizados como retentor intrarradicular surgiram com os avanços da odontologia adesiva, sendo uma opção relevante com inúmeras vantagens. A literatura odontológica aponta que a adaptação do pino às paredes do conduto radicular, somada a técnica de cimentação adesiva, são fatores essenciais para a longevidade do tratamento, sendo necessário em alguns casos sua personalização, para garantir melhor assentamento e promover prognóstico favorável. Objetivou-se neste artigo apresentar a técnica de preparo, personalização e cimentação do pino de quartzo na reconstrução de um dente tratado endodonticamente ilustrado por meio de caso clínico. Através de um protocolo ordenado e meticuloso da técnica de aplicação, foi possível alcançar o resultado desejado(AU)


Endodontic treatment often leads to loss of the coronary part of a tooth, either by weakening its structure, by traumatic lesions or by caries. Since under faborable conditions, these teetn can be restored by means of the biomechanical reinforcement promoted by the intraradicular retainers. The quartz posts have appeared with the advances of restorative dentistry, being a relevant option with numerous advantages. The dental literature indicates that the adaptation of the post to the root canal walls, together with the adhesive cementation technique, are essential factors for the longevity of the treatmet, being necessary in some cases its personalization, which guarantees its better settlement, avoiding the impression of undesirable forces to the tooth anf promoting better prognosis. The objective was to present the technique of preparation, personalization and cementation of the quartz post in the reconstruction of an endodontically treated tooth. Through an orderly and meticulous protocol of the application technique, it was possible to achieve the desired result(AU)


Subject(s)
Humans , Female , Adult , Quartz , Root Canal Filling Materials , Dental Cements , Dental Pins , Tooth, Nonvital
3.
Rev. Odontol. Araçatuba (Impr.) ; 40(2): 9-14, maio/ago. 2019. ilus
Article in Portuguese | LILACS, BBO | ID: biblio-1006302

ABSTRACT

A reabilitação funcional e estética com cerâmicas adesivas é uma área da Odontologia em destaque tanto pelos resultados excepcionais que podem ser alcançados como pela demanda da sociedade contemporânea. Várias ferramentas de diagnóstico, planejamento e execução estão disponíveis com o objetivo de alcançar a excelência no tratamento reabilitador estético. O desenho digital do sorriso (DSD) é um dos recursos utilizados, possibilitando além da previsibilidade, comunicação e orientação eficiente da fase laboratorial, também a motivação do paciente. O objetivo desse trabalho foi apresentar um caso clínico de reabilitação oral estética guiado pelo DSD tanto para a abordagem periodontal como para o enceramento estético. Foram planejados e executados 10 laminados cerâmicos em dissilicato de lítio tendo como ponto de partida após exames clínicos, o enceramento e a plástica periodontal virtualmente desenhados. O resultado foi alcançado como almejado pelo paciente e previsto pelo profissional, sendo a presente reabilitação apoiada em criterioso protocolo de execução(AU)


Functional and aesthetic rehabilitation with adhesive ceramics is an area of dentistry that stands out both for the exceptional results that can be achieved and for the demands of contemporary society. Various diagnostic, planning and execution tools are available with the goal of achieving excellence in aesthetic rehabilitation treatment. The digital smile design (DSD) is one of the resources used, enabling not only the predictability, communication and efficient orientation of the laboratory phase, but also the motivation of the patient. The objective of this work was to present a clinical case of oral aesthetic rehabilitation guided by DSD for both the periodontal approach and aesthetic waxing. Ten ceramic laminates in lithium disilicate were designed and executed with virtually new clinical waxing and periodontal plastic as a starting point after clinical examination. The result was achieved as intended by the patient and predicted by the professional, and the present rehabilitation is supported by a judicious implementation protocol(AU)


Subject(s)
Humans , Female , Adult , Photography, Dental , Esthetics, Dental , Mouth Rehabilitation , Ceramics
4.
RGO (Porto Alegre) ; 66(3): 250-256, July-Sept. 2018. tab, graf
Article in English | LILACS | ID: biblio-984899

ABSTRACT

ABSTRACT Objective: The aim of this study was to evaluate the satisfaction of patients rehabilitated with fixed partial denture and the incidence of failures/clinical complications of prostheses after one year. Methods: The patients answered a questionnaire about the satisfaction degree with dental treatment performed and care maintenance for prosthesis conservation. Clinical and radiographic evaluations of the prosthesis were performed. Data were tabulated for descriptive analysis of the factors assessed, with calculation of absolute frequencies and percentages, and chi-square and Fisher's exact test.. Results: A total of 9.67% failures were found. The most common was the prosthesis loosening (57.14%), followed by ceramic fracture (28.57%), and abutment tooth fracture (14.29%). Biological failures were observed in 30.65%. The most common failure was gingival recession (52.00%), periodontal pocket (24.00%), support periodontal involvement (16.00%), and recurrent caries (4.00%). Radiographic examination showed that 70.97% of the total number evaluated had some kind of failure. There was statistically significant association between satisfaction degree and technical failure (p=0.04). Conclusion: Patients were satisfied after observation period of 1 year. The main failures detected were: crown cementation failure and ceramic fracture; gingival recession, periodontal pocket; manufacture and cementation of short intraradicular post with increased diameter and crown cervical misfit.


RESUMO Objetivo: O objetivo deste estudo foi avaliar a satisfação dos pacientes reabilitados com prótese parcial fixa e a incidência de falhas/complicações clínicas das próteses instaladas após um ano. Métodos: Os pacientes responderam um questionário abrangendo o grau de satisfação pelo tratamento odontológico efetuado e os cuidados de manutenção realizados para a conservação da prótese. Na sequência foi realizada avaliação clínica e radiográfica das próteses. Os dados obtidos foram tabulados para análise descritiva dos fatores avaliados com cálculo de frequência absoluta e percentual, e teste de Qui-quadrado e Fischer. Resultados: Foram encontradas 9,67% de falhas, sendo a mais comum a descimentação (soltura da prótese) (57,14%), seguida da fratura da cerâmica (28,57%), e um caso de fratura no dente pilar (14,29%). As falhas biológicas foram observadas em 30,65%. A falha mais comum foi a recessão gengival (52,00%), seguida por bolsa periodontal (24,00%), envolvimento periodonto de suporte (16,00%), e recidiva de cárie (4,00%). No exame radiográfico 70,97% do número total avaliado apresentaram algum tipo de falha. Houve associação estatisticamente significante entre grau de satisfação e falhas mecânicas (p=0,04). Conclusão: Os pacientes ficaram satisfeitos após um período de acompanhamento de 1 ano. As principais falhas detectadas foram: falha de cimentação da coroa e fratura da cerâmica; Recessão gengival, bolsa periodontal; confecção e cimentação de pino intraradicular curto, pino com diâmetro aumentado e desajuste cervical da coroa.

5.
RGO (Porto Alegre) ; 65(3): 243-248, July-Sept. 2017. tab, graf
Article in English | LILACS, BBO | ID: biblio-896027

ABSTRACT

ABSTRACT Objective The aim of this study was to investigate the subjective aspects related to the perception of dental appearance and expectations of patients who receive dental treatment in graduation clinics of the Araçatuba Dental School. Methods It was evaluated 362 patients of both gender aged over 18. The questionnaire included questions of demographic data, questions to assess facial and dental aesthetics, dental satisfaction and treatments considering patients notion to improve dental esthetics. The data collected was analyzed using descriptive statistics and the chi-square test. Results The factor teeth for facial analysis and factor positioning in the arch for smile analysis were considered the most important subjects regarding the esthetic according to the respondents. 67.5% of patients were dissatisfied with the appearance of their teeth, and dissatisfaction with the color was the most important factor (66.8%). The treatment most desired was tooth whitening and 85.0% of patients said yes to it. Conclusion Respondents place great value on the teeth on the face appearance, and it can be seen that aesthetic treatments are highly valued in all age groups. There is a need for treatments to restore the function, but treatments to improve dental appearance were the most requested.


RESUMO Objetivo Avaliar os aspectos subjetivos relacionados à percepção da aparência dental e expectativas de pacientes que recebem tratamento odontológico nas clínicas de graduação da Faculdade de Odontologia de Araçatuba. Métodos Foram avaliados 362 pacientes de ambos os sexos com idade superior a 18. O questionário incluiu perguntas sobre dados demográficos, perguntas para avaliar a estética facial e dentária, a satisfação dental e tratamentos considerando a noção dos pacientes de melhorar a estética dental. Os dados coletados foram analisados por meio de estatística descritiva e o teste do qui-quadrado. Resultados O fator dentes para análise facial e o fator posicionamento no arco para análise sorriso foram considerados os temas mais importantes a respeito da estética, de acordo com os entrevistados. 67,5% dos pacientes estavam insatisfeitos com a aparência de seus dentes, a insatisfação com a cor foi o fator mais importante (66,8%). O tratamento mais desejado foi o clareamento dental e 85,0% dos pacientes disse sim a ele. Conclusão Os pacientes dão grande valor aos dentes sobre a aparência rosto, e ele pode ser visto que os tratamentos estéticos são altamente valorizados em todos os grupos etários. Há uma necessidade de tratamentos para restabelecer a função, mas os tratamentos para melhorar a aparência dentária foram os mais solicitados.

6.
Rev. odontol. UNESP (Online) ; 45(3): 171-176, tab, ilus
Article in English | LILACS, BBO | ID: lil-785869

ABSTRACT

Introduction: The biomechanical behavior of endodontically treated teeth depending on the selected restorative material and tooth situation to be restored. Objective: To analyze by the two-dimensional finite element method the biomechanical behavior of different diameters in intraradicular posts and teeth with coronal remaining of 2mm. Material and method: Six models were made with three types of posts, as follows: Glass fiber post, carbon fiber post, and cast metal post, both with diameter # 1 (1.1 mm in diameter) and # 2 (1.3 mm of diameter). The modeling was performed using the Rhinoceros 4.0 program. The FEMAP 10.2 and NEiNastran 9.2 programs were used to develop finite element models. The loading used was 100N for axial and oblique forces. The results were visualized using the von Mises stress map. The statistical analysis was made using analysis of variance (ANOVA) and Tukey post-test, with a significance level of 5%. Result: The oblique loading stress values were higher than the axial loading (p< 0.001) for both situations. The glass fiber post showed the lowest concentrations of stress on both loads (p< 0.001). The carbon fiber post presented significant difference compared to the cast metal post, only in the oblique load (p=0.007). The diameter did not increase the stress of the evaluated posts (p=0.302). Conclusion: The fiber posts were more favorable for restoration of endodontically treated teeth; the increase of diameter did not influence the increase of tension; the oblique load was more harmful for both posts and tooth structure.


Introdução: O comportamento biomecânico de dentes tratados endodonticamente é variável conforme o material restaurador selecionado e situação do dente a ser restaurado. Objetivo: Analisar por meio do método dos elementos finitos bidimensional o comportamento biomecânico de diferentes retentores intrarradiculares e diâmetros em dentes com 2mm de remanescente coronário. Material e método: Foram confeccionados seis modelos com três tipo de retentores: pino de fibra de vidro, pino de fibra de carbono e núcleo metálico fundido, ambos com diâmetro #1 (1,1mm de diâmetro) e #2 (1,3mm de diâmetro). A modelagem foi realizada através do programa Rhinoceros 4.0, e em seguida nos programas FEMAP 10.2 e NeiNastran 9.2 para desenvolvimento d os modelos de elementos finitos. Nos carregamentos foram utilizadas forças de 100N axial e oblíquo. Os resultados foram visualizados pelo mapa de tensão von Mises, e pela análise de variância (ANOVA) e pós-teste Tukey, com nível de significância à 5%. Resultado: O carregamento oblíquo apresentou maiores valores de tensões (p< 0,001). O pino de fibra de vidro apresentou menores concentrações de tensões em ambos os carregamentos (p< 0,001). O pino de fibra de carbono apresentou diferença significativa em relação ao núcleo metálico somente no carregamento oblíquo (p=0,007). O diâmetro não influenciou para o aumento de tensões dos retentores avaliados (p=0,302). Conclusão: Os pinos de fibras são mais favoráveis para restaurações de dentes tratados endodonticamente; O aumento do diâmetro não influenciou no aumento de tensões; A carga oblíqua é mais prejudicial à tanto para o retentor quanto para a estrutura dentária.


Subject(s)
Root Canal Filling Materials , Post and Core Technique , Dental Prosthesis , Finite Element Analysis , Dental Pins , Denture, Partial, Fixed , Tensile Strength , Analysis of Variance
7.
ImplantNewsPerio ; 1(5): 898-909, jul.-ago. 2016. ilus
Article in Portuguese | LILACS, BBO | ID: biblio-847698

ABSTRACT

Os procedimentos de enxertia óssea para ganho vertical ainda são temerários na Implantodontia. Não há um consenso na literatura sobre as técnicas para aumento em altura da crista óssea alveolar para futura colocação de implantes. Além disso, o tempo de tratamento é demasiadamente prolongado quando são realizadas as técnicas de enxerto ósseo com implantação tardia. Sendo assim, o objetivo deste trabalho foi descrever uma técnica para aumento ósseo vertical simultâneo à instalação de implante denominado bone ring. Paciente apresentando severo defeito ósseo em altura e largura na região do dente 14 foi reabilitada a partir da reconstrução óssea tridimensional com anel ósseo removido da área mentual e implantação imediata à fixação do enxerto. Após seis meses, foram realizados a reabertura e procedimentos protéticos de personalização de perfil de emergência, com posterior instalação de coroa metalocerâmica. Decorridos dois anos de acompanhamento, notou-se estabilidade tecidual peri-implantar sem remodelações severas do tecido ósseo peri-implantar. Pôde-se concluir que a técnica de reconstrução óssea tridimensional simultânea à instalação de implante ­ bone ring ­ é uma alternativa viável, mediante rigoroso planejamento e curva de aprendizado indicada para defeitos ósseos severos.


Bone grafting procedures for vertical bone augmentation are still an issue on implant dentistry. There is no literature consensus regarding techniques for alveolar ridge height increase for further implant placement. Besides, treatment times are extended in case of delayed implant placement. The aim of this paper was to describe a technique for vertical bone augmentation at the same time of implant installation (bone ring). A patient having a several bone defect in height and width at the region of tooth 14 received a 3D reconstruction with a bone ring removed from the chin area. Six months later, implant exposure was performed with procedures for soft tissue conditioning and delivery of a metalloceramic restoration. Tissue stability and no significant bone remodeling were observed after two years. The proposed technique for three-dimensional reconstruction ­ bone ring ­ is a viable alternative provided that judicious treatment planning and considerable learning curve are observed to manage severe bone defects.


Subject(s)
Humans , Female , Middle Aged , Alveolar Ridge Augmentation/methods , Biocompatible Materials , Bone Transplantation , Connective Tissue/transplantation , Dental Implants , Tissue Transplantation
8.
ImplantNewsPerio ; 1(2): 277-287, fev.-mar. 2016. ilus
Article in Portuguese | LILACS, BBO | ID: biblio-847356

ABSTRACT

O objetivo deste trabalho foi apresentar três casos clínicos de implantação imediata com provisionalização imediata, empregando a filosofia one abutment at one time. Nos três casos clínicos, após a realização das imagens tomográficas e prescrição medicamentosa, os implantes foram posicionados nas raízes mesiais (molares inferiores) e distovestibulares (molares superiores), sendo o espaço remanescente preenchido com biomaterial para preservação alveolar. Após a colocação dos pilares defi nitivos, coroas provisórias permaneceram por 90 dias até a cimentação das coroas metalocerâmicas definitivas. Os implantes são colocados abaixo do nível da crista óssea e o pilar utilizado constitui um exemplo de platform switching, que cria um espaço biológico e uma zona de selamento. Os controles destes casos vão de um a quatro anos demonstrando excelente estabilidade dimensional. Os resultados clínicos sugerem que a osseointegração de implantes unitários imediatamente carregados na região posterior pode ser alcançada. O uso de uma restauração provisória com a anatomia ideal de um dente molar pode facilitar a formação de contornos naturais da mucosa peri-implantar. É importante que o paciente não apresente bruxismo, possua osso suficiente para o posicionamento do implante e que pratique uma boa higiene oral.


The aim of this paper was to present three clinical cases with immediate implant insertion and provisionalization using the one abutment one time philosophy. On these, after CBCT and medicament prescription, the implants were positioned at the mesial (mandibular molars) and at the alveolar center (maxillary molars) aspects, being the gaps and the alveoli filled with a biomaterial for alveolar preservation. After the definitive abutments being placed, the provisional crowns remained in position for 90 days until cementation of the definitive metalloceramic crowns. The implants are placed below the bone crest level and the prosthetic abutment forms a platform-switching which creates a biologic space and a sealing zone. The follow-ups range from 1 to 4 years demonstrating excellent dimensional stability. The clinical results suggest that the osseointegration of immediate, single-tooth implants at the posterior region can be achieved. The use of a provisional restoration with ideal characteristics of a molar tooth facilitates the peri-implant mucosa contouring. It is important to select symptom-free bruxism patient, with sufficient bone for implant placement, and having good oral hygiene levels.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Dental Implantation , Dental Implants, Single-Tooth , Immediate Dental Implant Loading , Osseointegration
9.
Prosthes. Lab. Sci ; 6(21): 59-69, 2016. ilus
Article in Portuguese | LILACS, BBO | ID: biblio-837404

ABSTRACT

O objetivo deste artigo é apresentar um protocolo de tratamento de implantes imediatos de excelente previsibilidade estética e biológica. O caso clínico em questão apresenta comprometimento do elemento 21, que após o exame clínico e complementar constatou a fratura radicular irreparável. O planejamento foi a exodontia da raiz fraturada e instalação de implante imediato com provisionalização imediata, associando biomaterial para preenchimento do gap e enxerto conjunto na vestibular. Para restauração final foram confeccionadas uma coroa zircocerâmica como restauração definitiva do elemento 21 e uma microlâmina em dissilicato de lítio (IPS e.max) no dente 11 para harmonizar contorno e proporção entre os incisivos. O resultado final obtido mostrou-se favorável no follow-up de 1 ano, tanto nos aspectos biológicos dos tecidos peri-implantares e quanto à estética final. Com isso, concluímos que o protocolo adotado mostrou excelente previsibilidade.


The aim of this paper is to present a treatment protocol for excellent aesthetic and biological predictability with immediate implant. In the reported clinical case, the element 21 was compromised with irreparable root fracture. The planning was the extraction of the fractured root and immediate implant placement with immediate temporization, associating biomaterial for gap filling and conjunctive tissue graft. for the final restoration were made a zirco-ceramic crown in the element 21, and a lithium disilicate veneer (IPS e.max) in tooth 11 to harmonize contour and ratio between the incisors. The final result was favorable along the 1 year follow-up for both biological aspects of peri-implant tissues and final aesthetic. Thus, it could be concluded that the adopted protocol showed great predictability.


Subject(s)
Humans , Female , Adult , Biocompatible Materials , Connective Tissue/transplantation , Dental Implants, Single-Tooth , Immediate Dental Implant Loading , Surgery, Oral , Transplantation, Autologous
10.
Rev. odontol. UNESP (Online) ; 44(5): 262-267, set.-out. 2015. tab
Article in English | LILACS, BBO | ID: lil-763343

ABSTRACT

Introduction: Temporary restorative materials are widely used, however, little is know about their color stability. Objective: to evaluate the color stability of the following temporary restorative materials: acrylic and bis-acrylic resins after immersion in pigmenting solutions for different periods of storage. Material and method: Four materials were tested (Dêncor/Clássico, Protemp 4/3M ESPE; Structur 2 SC/Voco; Luxatemp AM Plus/DMG) and 30 test specimens (15 mm in diameter and 2 mm thick) per material were fabricated. They were divided according to the storage medium (artificial saliva, saliva + cola type soda, and saliva + coffee) and storage time intervals (2, 5, 7 and 15 days). Color measurements were made before and after immersions, with use of a spectrophotometer, by means of the CIE L*a*b* system. The data were analyzed by the analysis of variance and the Tukey Test, at a level of significance of 5%. Result: Acrylic resin presented greater color stability in comparison with bis-acrylic resins (p<0.001). When bis-acrylic resins were compared no significant difference was observed between the resins Structur and Luxatemp (p=0.767). As regards solutions tested, coffee showed the highest color change values (p<0.001), and the longer the storage time interval, the greater was the color change in all the temporaryrestorative materials analyzed (p<0.001). Conclusion: Acrylic resin presented greater color stability in comparison with bis-acrylic resins (p<0.001). Coffee caused the greatest color change, and immersion time was determinant in color stability of the temporary materials analyzed.


Introdução: Os materiais restauradores provisórios são amplamente utilizados, porém pouco se sabe a respeito de sua estabilidade de cor. Objetivo: Avaliar a estabilidade de cor de materiais restauradores provisórios: resina acrílica e resinas bisacrílicas, após a imersão em soluções pigmentantes, durante diferentes períodos de armazenamento. Material e método: Quatro materiais foram testados (Dêncor/Clássico, Protemp 4/3M ESPE; Structur 2 SC/Voco; Luxatemp AM Plus/DMG) sendo confeccionadas 30 amostras (15 mm de diâmetro e 2 mm de espessura) por material. Estes foram divididos de acordo com o meio de imersão (saliva artificial, saliva + refrigerante tipo cola e saliva + café) e período de armazenamento (2, 5, 7 e 15 dias). As mensurações de cor foram realizadas antes e após as imersões, com auxílio de um espectrofotômetro, através do sistema CIE L*a*b*. Os dados foram analisados com análise de variância (ANOVA) e Tukey, com nível de significância à 5%. Resultado: A resina acrílica apresentou maior estabilidade de cor quando comparada às resinas bisacrílicas (p<0,001). Comparando as resinas bisacrílicas, não foi observado diferença significativa entre as resinas Structur e Luxatemp (p=0,767). Em relação as soluções testadas, o café apresentou os maiores valores de alteração de cor (p<0,001), sendo que quanto maior o período de armazenamento, maior foi a alteração de cor de todos os materiais provisórios analisados (p<0,001). Conclusão: A resina acrílica apresentou maior estabilidade de cor, quando comparada às bisacrílicas. O café causou a maior alteração de cor, e o tempo de imersão foi determinante na estabilidade de cor dos materiais provisórios analisados.


Subject(s)
Spectrophotometers , Analysis of Variance , Dental Prosthesis , Color , Dental Restoration, Temporary , Acrylic Resins , Coffee
11.
Braz. dent. j ; 26(3): 284-287, May-Jun/2015. tab, graf
Article in English | LILACS | ID: lil-751861

ABSTRACT

This in vitro study evaluated the effect of mechanical cycling on the torque of retaining screw in external hexagon implants with platform switching (PS), regular platform (RP) and wide platform (WP). A total of 30 specimens were equally divided into 3 groups: PS, PR and WP. Each specimen was prepared with implants: 3.75 x 10 mm for RP group and 5.0x10 mm for PS and WP groups and its respective abutment with 32 Ncm torque. All groups were subjected to 106 cycles with 100 N (corresponding to about 40 months of chewing). The results were obtained with the reverse torque of each specimen and data were evaluated using ANOVA and Tukey test (p<0.05). The PS group showed statistically significant difference in screw removal torque (30.06±5.42) compared with RP (23.75±2.76) and WP (21.32±3.53) (p<0.05) groups; the RP and WP groups showed no statistically significant difference between them. It was concluded that the PS group showed higher reverse torque value, suggesting lower susceptibility of the abutment screw loosening.


Este estudo in vitro avaliou o efeito da ciclagem mecânica no torque dos parafusos de retenção em implantes de hexágono externo com plataforma switching (PS), plataforma regular (RP) e plataforma larga (WP). Foram utilizados 30 corpos de prova divididos em 3 grupos equitativamente: PS, RP e WP. Cada corpo de prova foi preparado com implantes: 3,75x10 mm para o grupo RP e 5,0x10 mm para os grupos PS e WP, e seu respectivo abutment com o torque de 32 Ncm. Todos os grupos foram submetidos a 106 ciclos com 100 N de força (o que corresponde a aproximadamente 40 meses de mastigação). Os resultados foram obtidos com o torque reverso de cada espécime e os dados foram avaliados com ANOVA comparado com o teste de Tukey (p<0,05). O grupo PS apresentou diferença estatisticamente significante no torque de remoção do parafuso (30,06±5,42) comparado com os grupos RP (23,75±2,76) e WP (21,32±3,53) (p<0,05); os grupos RP e WP não apresentaram diferença estatisticamente significante entre si. Concluiu-se que o grupo PS apresentou maior valor de torque reverso sugerindo menor susceptibilidade de afrouxamento do parafuso de fixação do abutment.


Subject(s)
Bone Screws , Dental Implants , Prosthesis Design , Torque
12.
Braz. j. oral sci ; 14(1): 36-40, Jan-Mar/2015. tab, graf
Article in English | LILACS | ID: lil-745786

ABSTRACT

To evaluate the adherence of Streptococcus mutans to the surface of the amalgam and copper/aluminum alloy samples and also evaluate the release of metallic ions. METHODS: The prepared medium was changed every 72 h and analyzed by atomic absorption spectrophotometer. Samples were removed from the prepared medium at 15, 30, 48 and 60 days. RESULTS: The result shows that ions released were statistically different among all groups, and so were both biofilm and pits formation and the corrosion induced by the S. mutans in both types of samples. SEM observation of the samples immersed in the prepared medium with S. mutans showed adherence of microorganisms on the whole surface, in all groups. CONCLUSIONS: The S. mutans adhere to both amalgam and copper/aluminum alloy causing corrosion of those restorations. S. mutans produced a greater ions release in Cu/Al alloy; in amalgam, the ions release was not influenced by exposure to S. mutans...


Subject(s)
Humans , Corrosion , Dental Alloys , Dental Amalgam , Ions , Streptococcus mutans
13.
Full dent. sci ; 6(21): 82-88, dez. 2014. ilus
Article in Portuguese | LILACS, BBO | ID: lil-750186

ABSTRACT

Algumas vezes nos deparamos no consult¢rio com situa‡ães cl¡nicas, nas quais a falta de harmonia no sorriso encontra-se devido a uma grande exposi‡Æo de tecido gengival. Nestes casos o profissional deve ser capaz de realizar uma an lise detalhada dos componentes est ticos e dinƒmicos do sorriso, em busca de um planejamento e tratamento satisfat¢rios, que poder  englobar diferentes especialidades odontol¢gicas. Para estas situa‡ães, a associa‡Æo periodontia/pr¢tese ‚ uma alternativa vi vel a ser proposta ao paciente, que vem sendo utilizada de maneira positiva em busca de uma condi‡Æo est‚tica e funcional favor vel ao paciente, sem deixar de lado os princ¡pios de preserva‡Æo dos tecidos periodontais e da estrutura dent ria remanescente. Diante disso, o objetivo deste trabalho foi descrever um caso cl¡nico no qual a associa‡Æo periodontia/pr¢tese foi proposta para corre‡Æo de sorriso gengival e vestibulariza‡Æo dent ria. Atrav‚s do resultado cl¡nico obtido e a satisfa‡Æo do paciente, podemos entender que o tratamento multidisciplinar envolvendo a associa‡Æo de t‚cnicas periodontais e prot‚ticas em casos com comprometimento est‚tico gengival e dental, ‚ favor vel para alcan‡ar um resultado positivo.


Sometimes we face clinical situations in which the lack of harmony in the smile is caused by a major exhibition of the gingival tissue. In these cases the professional should be able to perform a detailed analysis of the static and dynamic components of the smile, in search of a satisfactory planning and treatment which may include different dental specialties. For these situations, the association of periodontics/prosthesis is a viable alternative that has been used positively in search of an aesthetic and functional condition that benefits the patient, without leaving aside the preservation of periodontal tissues and of the remaining structure of the tooth. Thus, the aim of this study was to describe a case in which the association between these two areas was proposed to correct gummy smile and dental vestibularization. Clinical results and the satisfaction of the patient indicate that this multidisciplinary treatment combining periodontal and prosthetic techniques is favorable to positive results in cases of compromised smile aesthetics due to excessive gum tissue.


Subject(s)
Humans , Female , Adult , Ceramics/therapeutic use , Periodontal Diseases/therapy , Dental Veneers , Gingivoplasty , Patient Satisfaction , Smiling/psychology , Patient Care Planning , Dental Prosthesis , Surgical Procedures, Operative
14.
Rev. Assoc. Paul. Cir. Dent ; 68(4): 312-318, out.-dez. 2014. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-745430

ABSTRACT

Objetivo: Avaliar a precisão da técnica de transferência de implantes sem material de moldagem, comparando-a ao posicionamento dos implantes de um modelo padrão. Material e Método: modelo em resina acrilica com três implantes instalados na área dos dentes 35 e 36 foi reproduzido, obtendo-se três modelos cujas áreas dos implantes foram recortadas para permitir a transferência dos mesmo. No modelo padrão os transferentes foram unidos com resina duralay estendendo-se às porções oclusais dos dentes adjacentes aos implantes. Após a polimerização os transferentes foram desparafusados, conectados aos análogos e posicionados nos modelos reproduzidos, pelas extensões da resina nas superfícies oclusais dos dentes que limitam o espaço e vertido gesso tipo IV. O modelo padrão e os 3 modelos foram fotografados pelas superfícies vestibular e oclusal, com distância igual para todos os modelo. As alterações de posicionamento dos implantes, decorrentes de suas transferências, foram mensurada pelo programa Corei Draw 3, comparando-se as medidas do modelo padrão com as dos modelos obtidos. Resultados: Foram observados alterações das posições de todos os implantes transferidos sendo no sentido mesial, para todos os implantes (A, B e C) no sentido bucal para os implantes A e B e vestibular para o implante C. Conclusões: Todos os valores dos implantes transferidos forma menores do que 0,5 graus e a diferença entre os valores do modelo padrão e a média dos valores dos modelos transferidos pode ser suficiente para influenciar no assentamento passivo entre as estruturas.


Objective: Analyze the accuracy of implants transfer technique without impression materia comparing it to the implants positioning of a standard model. Material and Method: A standard modei with three dental implants inserted in the region 35 and 36 teeth was reproduced, getting three models (1. 2 and 3) whose areas of implants were cut to allow its transference.ln the standard model squares transfer were installed and splinted with acrylic resin (duralay reliance Dental Mfg Co. Wort ll). The acrylic resin extension involved the adjacent teeth occlusalsurfaces. After polymerization, transfer screws were unscrewed, connected to the implants analogues and adapted. To reproduceí casts, the acrylic resin extensions that limited the space, and the implants analogues fixed wit dental stone type IV (Durone; Dentsply Industry and trade Ltd, Petropolis, RJ, Brasil). Both standan model and reproduced casts (1,2 and 3) were photographed through buccal and occlusal surfaees with Nikon D50 camera, Macro lens 105mm and flash (Siqma], on stative and distance camera/object determined and maintained equal for all models photographed and measured by Corei Draw 3 program. Results: Were observed changes in the positions of all implants transferred in mesial direction(A, B and C), bucal direction (A and B) and vestibular direction (C). Conclusions: All values of implants transferred were smaller than 0,5 degree and the difference between the values of the Stander mode and transferred casts may be sufficient to influence the passive fit between the structures.


Subject(s)
Dental Implants , Prostheses and Implants , Dental Impression Technique
15.
Rev. cir. traumatol. buco-maxilo-fac ; 13(3): 9-16, Jul.-Set. 2013. ilus
Article in Portuguese | LILACS | ID: lil-792276

ABSTRACT

A implantodontia apresenta elevadas taxas de sucesso e previsibilidade nesta década, entretanto a disponibilidade óssea é um fator que pode limitar a técnica de instalação de implantes osseointegráveis. Nas reabilitações do arco superior posterior, têm sido propostas técnicas de levantamento do seio maxilar, quando este se apresenta pneumatizado para a instalação de implantes osseointegrados. O objetivo do artigo é apresentar por meio de dois casos clínicos a técnica cirúrgica e a reabilitação do paciente com cirurgia de levantamento do seio maxilar, apenas com a utilização de biomaterial ou associado a osso autógeno, bem como a resolução protética e acompanhamento clínico radiográfico de 3 anos.


The implant has high success rates and predictability in this decade. However, bone availability is a factor that may limit the installation technique of dental implants in subsequent rehabilitation of the maxillary arch has been proposed technique's maxillary sinus lifting when it presents itself pneumatized, for installation of dental implants The aim of this paper is to present two clinical cases using the surgical technique and rehabilitation to the patient with surgery maxillary sinus lifting with the use of a biomaterial alone or in combination with autogenous bone and the prosthetic resolution radiographic and clinical follow-up of three years.

16.
Full dent. sci ; 4(13): 186-194, out.-dez. 2012. ilus
Article in Portuguese | LILACS, BBO | ID: lil-681691

ABSTRACT

O escurecimento dental de origem medicamentosa pela ingestão da tetraciclina repercute negativamente na aparência do sorriso. A tetraciclina quando utilizada no período em que os dentes estão sendo formados pode induzir a formação de manchas de coloração amarelada ou marrom-acinzentada na estrutura dentária. Seu uso quando os dentes já estão formados ou erupcionados na cavidade bucal não provoca alterações perceptíveis nos elementos dentários. Os tratamentos indicados para essa ocorrência contemplam a microabrasão, clareamento e laminados. Este trabalho teve como objetivo apresentar os cuidados para o planejamento estético em casos de manchamentos dentários por tetraciclina, e a descrição clínica para execução de laminados cerâmicos confeccionados em IPS E-max (Ivoclar - Vivadent). A harmonia e estética obtidas na conclusão do caso traduzem a saúde e conforto devolvidos ao paciente para o tratamento proposto


The darkening of teeth caused by tetracycline ingestion affects the appearance of the smile in an undesirable way. When used during teeth formation period tetracycline can induce the appearance of yellow or grayish-brown stains in the dental structure. Its use does not cause noticeable changes in the teeth when the teeth are already formed or erupted in the oral cavity. In these cases recommended treatments includes micro abrasion, tooth whitening and ceramic veneers. This paper aimed at presenting aspects that must be observed on aesthetic planning on cases of dental staining caused by tetracycline, as well as describe clinical steps for the execution of ceramic laminates produced using IPS E-max (Ivoclar -Vivadent). Harmony and aesthetics results obtained after the treatment are reflected on the restoration of patient’s health and comfort


Subject(s)
Humans , Female , Adult , Dental Cements/chemistry , Esthetics, Dental , Dental Veneers , Computer-Aided Design , Tetracycline/administration & dosage
17.
Clín. int. j. braz. dent ; 8(3): 310-322, jul.-set. 2012. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-716634

ABSTRACT

O avanço no campo da tecnologia adesiva e dos materiais indiretos se reflete no aumento da aplicação das restaurações indiretas adesivas que utilizam a resina laboratorial indireta (cerômero), permitindo ao clínico alcançar resultados funcionais e estéticos satisfatórios. Este trabalho apresenta os detalhes técnicos para a realização de inlays de resina laboratorial indireta nos dentes posteriores, enfatizando a técnica de selamento dental imediato ou pré-hibridização, ilustrando as etapas clínicas para se obter sucesso longitudinal


Advances of the adhesive technology and indirect materials resulted in the increased use of indirect restorations. The use of adhesive indirect resins (ceromers), allows the dentistry to achieve satisfactory functional and esthetic results. This paper presents the technical details to produce indirect resin inlay-type restorations, emphasizing the technique of immediate dental sealing or pre-hybridization, illustrating the steps to achieve clinical long-term success


Subject(s)
Humans , Male , Adult , Dental Materials , Esthetics, Dental , Inlays , Resins, Synthetic
18.
Clín. int. j. braz. dent ; 7(2): 166-176, abr.-jun.2011. ilus
Article in Portuguese | LILACS | ID: lil-757833

ABSTRACT

O aumento da demanda por tratamentos estéticos, aliado ao desenvolvimento de materiais e técnicas, converge para a reconstrução de sorrisos com resultado altamente satisfatório, no que tange à estética e à durabilidade e resistência dos tratamentos restauradores. Os sistemas cerâmicos atuais apresentam propriedades físicas e ópticas que simulam as características naturais dos elementos dentários e proporcionam sucesso a longo prazo. Este artigo descreve a execução de coroas all-ceram em incisivos centrais superiores, bem como os passos clínicos para a confecção das restaurações cerâmicas nos dentes anteriores...


The increased demand for esthetic treatments along with the development of materials and techniques, allow for the professional to obtain highly pleasant results through lasting, esthetic, and strong restorations. Current ceramic systems present physical and optical properties that mimic the natural characteristics of teeth, providing long-term successful restorations. This article describes the fabrication of All-Ceram crowns for central maxillary incisors, as well as the clinical steps for the fabrication of ceramic restorations on anterior teeth...


Subject(s)
Humans , Female , Adolescent , Ceramics , Crowns , Esthetics, Dental
19.
Rev. dental press estét ; 7(4): 68-78, out.-dez. 2010. ilus
Article in Portuguese | LILACS, BBO | ID: lil-578151

ABSTRACT

A percepção e o alcance da excelência estética traduzem-se especialmente em saber interpretar e satisfazer os anseios dos pacientes, empregando-se para isso todo o conhecimento disponível na literatura científica. No tratamento com laminados cerâmicos, a ciência fornece parâmetros para nos guiar com relação a um correto diagnóstico, planejamento seguro, técnica adequada e material mais indicado; porém, a subjetivide estética pode estar escondida nas entrelinhas da ciência. Contudo, o objetivo deste artigo é descrever um protocolo para fechamento de múltiplos diastemas, salientando a técnica empregada, bem como o material cerâmico utilizado e suas peculiaridades, implícitas dentro de um contexto estético específico.


Subject(s)
Humans , Female , Young Adult , Composite Resins , Dental Porcelain , Diastema , Dental Cements , Dental Materials , Esthetics, Dental
20.
Araçatuba; s.n; 2009. 52 p. ilus.
Thesis in Portuguese | LILACS, BBO | ID: lil-671253

ABSTRACT

Objetivo: O propósito deste estudo foi avaliar o padrão de tensão produzido por overdentures implanto-retidas com 3 diferentes sistemas de retenção e prótese fixa tipo protocolo de Branemark, através do método da fotoelasticidade. Método: O modelo mandibular foi confeccionado em resina fotoelástica PL-2 contendo 4 implantes 3.75x10mm, posicionados na área interforaminal. Foram avaliadas 4 situações clínicas: A- Overdenture com 3 attachments clip sobre barra; B- Overdenture com 2 attachments Era em cantilever aos últimos implantes e 1 clip anterior; C- Overdenture com 3 attachments O’ring sobre barra e DPrótese total fixa tipo protocolo de Branemark. Forças oclusais verticais de 100N foram aplicadas entre os incisivos centrais e unilateralmente nos segundos premolares direito e esquerdo e segundos molares direito e esquerdo para todos os sistemas. Na prótese protocolo foram aplicadas cargas verticais nos primeiros molares a fim de permitir análise da extensão do cantilever. As tensões desenvolvidas nas estruturas de suporte foram monitoradas fotoelasticamente e registradas fotograficamente. Resultados: No carregamento anterior, houve alta concentração de stress nos implantes medianos na situação A, principalmente na região apical. O carregamento no premolar gerou alto stress no implante ipsilateral à aplicação da carga com maior intensidade para a prótese protocolo e situação A. No carregamento do molar, a overdenture com 3 o’ring distribuiu o stress de forma mais uniforme sobre o rebordo alveolar, com menor sobrecarga ao implante distal. O aumento do cantilever na prótese protocolo causou grande stress ao último implante e tração no implante mediano. Todas as situações avaliadas demonstraram baixa transferência de stress ao nível do pescoço dos implantes contralaterais à aplicação da carga. Conclusão: As forças verticais aplicadas na overdenture com 3 clip e prótese protocolo geraram um imediato padrão de stress de grande concentração e magnitude sobre o...


Objective: The purpose of this study was to evaluate of stress patterns produced by mandibular implant overdentures with three different attachment systems and fixed implant prosthesis, through the photoelastic method. Method: A mandibular model was fabricated PL-2 photoelastic resin having 4 screw-type implants (3.75 × 10 mm) embedded in the parasymphyseal area. Four clinical situations were evaluated: A - Overdenture with 3 plastic Hader clips on bar; B - Overdenture with 2 ERA attachment was in cantilever to the terminal implant and 1 anterior Hader clip; C - Overdenture with 3 ball/O-ring attachment on bar and D - implant-supported fixed partial denture (FPD). Vertical occlusal forces from 100 N were applied between of central incisor and unilaterally to the right and left second premolars and second molars for all the designs. In FPD were applied vertical loads in the first molars in order to allow analysis of the cantilever extension. Stresses that developed in the supporting structure were monitored photoelastically and recorded photographically. Results: Anterior loading, there was high stress concentration in medium implant in the situation A, mainly apical area. The premolar loading generated high stress to the ipsilateral implants with larger intensity from the FPD and situation A. The molar loading, the overdenture with 3 ball/O-ring attachment away the caused more uniform stress distribution in the posterior edentulous ridge with less overload in the terminal implant. The FPD cantilever increase caused high stress to the terminal implant and traction to the medium implant. All the situations demonstrated a low stress transfer at the level of the contralateral implants neck. Conclusion: Vertical forces applied to the bar-clip overdenture and FPD created immediate stress patterns of greater magnitude and concentration on ipsilateral implants while the ball/O-ring attachments transferred minimal stress to implants. The clinical implication of the...


Subject(s)
Dental Implantation , Dental Prosthesis , Dental Prosthesis, Implant-Supported , Dental Stress Analysis
SELECTION OF CITATIONS
SEARCH DETAIL